AutoView Commander Installer/User Guide
Attaching Multiple AutoView Units
1. Follow steps 1-6 of the Basic Install section.
2. Plug the 25-pin “D” connector of your input cable into any available
channel port on the rear of your base AutoView unit.
3. Plug the 15-pin video connector on the other end of the cable into the
port labelled
on your first cascading AutoView unit. Plug the PS/2
mouse connector, designated by a yellow band or mouse icon, into the
port. Plug the remaining 6-pin miniDIN keyboard connector into the
port. The 9-pin serial and 5-pin DIN connectors are not used for
cascading.
4. Repeat steps 2-3 for every cascaded AutoView unit in your system.
5. Power up your AutoView unit(s) first, then all attached computers.